Performance evaluation report : ACC-009
Eye-diagram epsification differencies between ways of connection
ACC-009 converts HuMANDATA's SIF40 standard interface into SMA connectors.
For your reference, please see the following Eye-diagram and specifications when we use ACC-009 to ouput fast serial transceiver(Tx) signals from the SIF40 connector.
Most pictures are available to zoom.
ACM-024 is used as a signal generator for measurement. The ACC-009 is connected to ACM-024's SIF40 connector to output fast serial signals.
Signal Spec: Channel: 0(P) |
Between Gen and Oscillo | Eye Diagram | Jitter Analysis |
---|---|---|
Direct |
||
|
||
conversion board + ACC-009 |
These datas show you transmission characteristics measured by network analyzer. The one of measured differential pair is connected to analyzer and the another is terminated by 50 Ohm resister.
Connection (Single Side) | result (S21) | Note |
---|---|---|
Direct |
for calibration | |
|
|
|
conversion board + ACC-009 |
[ ]